The original Wycombe Hospital site on Marlow Hill in Buckinghamshire started as the High Wycombe War Memorial Hospital, which opened in 1923. The current hospital, Wycombe Hospital, was built in phases on a site adjacent to the old Memorial Hospital with Phase 1 being completed in 1966, Phase 2 being completed in 1969 and Phase 3 being completed in 1971. The existing podium level car park constructed of reinforced concrete was believe to have been part of the 3rd phase of construction.
PROBLEM AND SOLUTION
The existing parking deck had a rough tamped concrete surface which didn’t have a waterproofing membrane applied to it at the time of the refurbishment. Working as a specialist sub-contractor partner to the Principal Contractor, the works commenced. Jet washing was carried out to the upper car park parapet walls, followed by breaking out and repair of defective concrete.
A migratory corrosion inihibitor (MCI) was then applied to the parapet walls and the car park soffits below, followed by concrete repairs and the application of anti-carbonation coatings throughout.
OUTCOME
Sika’s rapid curing Pronto® car park deck waterproofing system was applied to the entire upper parking deck followed by the reinstatement of new line marking for parking bays, directional arrows & and instructions. On completion of the project, the warranty certificate was issued to our client. We were delighted to receive the following testimonial from our client: “Following the completion of works at Wycombe Hospital, I just wanted to thank you and the team for your efforts in getting everything over the line – much appreciated.”